ADE100 Magnetic Contactor
Product Features
, Ceramic Brazing Sealing Technology, No Risk of Arc Leakage, Ensure No Fire and Burst;
2, potting hydrogen-based gas, effectively preventing oxidation and burning of contacts, low and stable contact resistance, contact part can meet IP67;
3, 40A 85 ℃ long-term current carrying capacity;
4 4, meet the requirements of abnormal working conditions, able to break 10 times over current;
5, insulation resistance up to 1000MΩ(1000VDC), dielectric withstand voltage meets IEC60664-1 requirements.
Keyword: ADE100 Magnetic Contactor
Product Details
For a long time, the company has won extensive trust and support from customers with its ever-increasing innovation capabilities, stable quality assurance capabilities, professional customization capabilities, timely delivery capabilities and high-quality after-sales service system. Volkswagen, Komatsu, Dongfeng, GOODWINCH, TMAX and other major companies have formed close strategic partnerships.The company has strong research and development capabilities, precise production equipment, advanced production technology, sophisticated testing equipment and a million-level purification workshop. There are more than 20 series of products with a total of more than 1000 specifications, such as high and low voltage DC contactors, power switches, connectors, etc, it is widely used by customers in new energy electric vehicles and supporting charging stations and charging piles, photovoltaic and wind power generation systems, energy storage power stations, battery packs, electric forklifts, electric winches, battery cars, electric locomotives, UPS, medical equipment, communication power supplies, Inverter, power backup and other fields, and are exported to Asia, Europe and America.Today, all Okai people are refreshed and enterprising! Facing the market and customers, we have only one promise: Okay, let the electricity be in control!
Magnetic contactors are essential components in electrical control systems due to their ability to handle high currents and voltages. They are commonly used in applications such as motor control, lighting control, and HVAC systems. The key advantage of using a magnetic contactor is that it allows for remote control of power circuits, providing an efficient and safe way to operate heavy machinery without direct manual intervention. These contactors are designed for frequent switching operations and can withstand the rigors of continuous operation, making them highly reliable in industrial environments.
One important feature of magnetic contactors is their overload protection capability. They are equipped with thermal overload relays that monitor the motor's current and temperature. If the current exceeds the rated capacity or if the motor overheats, the thermal overload relay trips and disconnects the power supply to protect the motor from damage. This feature is crucial in preventing motor burnout and enhancing overall system safety. Additionally, some magnetic contactors offer built-in auxiliary contacts for control signaling, allowing for integration with other control devices to enable advanced functionality and automation in electrical systems.
| Electrical Characteristics | ||
|
Insulation Resistance |
Contact | 1000MΩ(1000VDC) |
| Contact and Coil | 1000MΩ(1000VDC) | |
| Contact and Housing | 1000MΩ(1000VDC) | |
|
Dielectric Withstand Voltage |
Disconnect Contacts | 3000VAC/1min |
| Contact and Coil | 4000VAC/1min | |
| Mechanical Characteristics | ||
|
Shock |
Stability | 196m/s² ;98 m/s |
| strength | 490 m/s | |
| vibration | 10~500Hz 49 mm/s | |
| life expectancy | ||
| mechanical life | 200,000 cycles | |
|
resistive load life (switching) |
6 × 10 3 times(100A,450VDC) | |
| 6 × 10 3 times(100A,750VDC) | ||
|
capacitive load life (closed only) |
- | |
| - | ||
| conditions of use | |||
| working environment temperature | -40 ℃ ~ +85 ℃ | ||
| Working Environment Humidity | 5% RH ~ 85% RH | ||
| Protection Level | IP67 | ||
| Overall Dimension | 81.5mm × 40.0mm × 78.3mm | ||
| Weight | ≈ 400g | ||
| main contact parameter | |||
| contact form | 1K | lead-out mode | M6 external thread M6 External Thread |
| standard contact resistance | ≤ 10mΩ(@ 6VDC 20A) | rated load voltage | 12-750VDC |
| rated load current | 100A | maximum switching power | 450V 45kW 750V 75kW |
| minimum load | 1A 12VDC | standard continuous live current (40mm conductor) | 100A |
|
short-term overload current (40mm @ 40 ℃) |
100A: continuous Continuous; 120A:2h; 200A:10min; 400A:2min; 600A:30s; 1000A:0.6s; |
||
| coil parameter | ||
|
parameter name |
standard voltage | |
| 12VDC | 24VDC | |
| operating voltage | 9~16 | 18~32 |
| Maximum Voltage | 16 | 32 |
| Action Voltage | ≤ 75% | ≤ 75% |
| Release Voltage | ≥ 8% | ≥ 8% |
| Coil Resistance (10%)(Ω) | 48 | 190 |
| minimum starting current (A) | 0.25 | 0.13 |
| transient surge current (A) | - | - |
| average holding current (A) | 0.25 | 0.13 |
| steady-state power consumption (W) | 3 | 3 |
| action time (ms) | ≤ 30 | ≤ 30 |
| release time (ms) | ≤ 10 | ≤ 10 |
| bounce time (ms) | ≤ 5 | ≤ 5 |